Official websites use .gov
A .gov website belongs to an official government organization in the United States.
A .gov website belongs to an official government organization in the United States.
A lock or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites
![]() |
Emergency responders may encounter incidents involving self-inflicted chemical exposure via toxic gas generation. The most frequent methods involve mixing household or industrial chemicals to produce high-risk gases, including hydrogen sulfide, hydrogen cyanide, sodium nitrite (acidified), and carbon monoxide. First responders must immediately implement hazmat protocols, utilize appropriate PPE/respirators, and secure the perimeter to avoid secondary exposure and prevent the gas from spreading.
*If you arrive on scene and the person has attempted suicide, but is not deceased, take precautions to protect yourself and begin emergency care/resuscitation practices.
Indicators that a scene may be a chemical suicide include:
A confined space (e.g., a car or room with closed doors and windows)
Tape or plastic covering the vents and windows
A person showing no signs of trauma
Signs or placards posted by the person warning of toxic gas
A suicide note
Empty cleaning supply, pesticide, or paint containers
Odors such as rotten eggs or bitter almonds
Other personnel near the area complaining of symptoms such as difficulty breathing
Consider apparent deaths from chemical exposures in these situations may be suicides, homicides, or accidents
For more detailed information and pictures on identifying key components of a chemical suicide: https://info.publicintelligence.net/CFIX-ChemicalSuicide.pdf
Carbon Monoxide (CO) suicide is usually achieved by inhaling exhaust from vehicles, generators, or fuel-based heaters in an enclosed space. CO is an odorless, colorless gas that can kill by displacing circulating oxygen.
The same protocols should be followed for CO suicide as for other mixed chemical suicides. The most common chemical mixtures used are Hydrogen Sulfide, Hydrogen Cyanide and Sodium Nitrite due to availability and ease of use.
| Hydrogen Sulfide | Hydrogen Cyanide | Sodium Nitrite | |
|---|---|---|---|
| About | Made by mixing cleaning components containing acid with compounds containing sulfur, like pesticides or insecticides. Creates a gas that asphyxiates on the cellular level. | Created using an acid source and cyanide salts such as sodium cyanide or potassium cyanide. Less common because components harder to obtain. | Sodium Nitrite (NaNO2) is a water-soluble, white-yellow colored crystalline powder typically used as a food preservative, antimicrobial, a coloring agent, and in automotive maintenance. When ingested, it interferes with the ability of red blood cells to transport oxygen, proving fatal. |
| Exposure Route | Inhalation | Mucous membranes, eyes, skin | Ingestion |
| Odor Note: High concentrations can lead to olfactory fatigue, making the scent undetectable |
Rotten egg | Bitter almond | None |
| Symptoms |
|
|
|
| Initial Isolation distance | 100 ft | 200 ft | 150 ft |
| Protective Action Distance | 0.1 miles (day) and 0.3 miles (night) | 0.1 miles (day) and 0.4 miles (night) | Avoid contact with Sodium Nitrite |
| Dangerous Concentration Levels |
|
|
|
| Patient Treatment |
|
|
|
Chemical suicides should be treated as a hazardous materials (HAZMAT) incident and a crime.
When responding:
Size up the event scene
Request a HAZMAT Team and assistance from law enforcement
Wear appropriate PPE and respiratory protection
Secure the area
Attempt to determine whether person is still alive or deceased
Initiate rescue for viable patients
Ventilate the confined space
Perform atmospheric monitoring for toxic gases
Decontaminate those who have been exposed
Begin recovery operations
Protect evidence and prepare for a criminal investigation
Consider additional risks
General guidance on PPE for responding to chemical suicide as follows:
Respiratory Protection: Use a NIOSH-approved self-contained breathing apparatus Self-Contained Breathing Apparatus (SCBA) or combination SCBA and type C supplied-air respirator with full-face mask when entering areas with unknown chemical concentrations or Immediate Danger to Life or Health (IDLH) conditions.
References: NIOSH Pocket Guide to Chemical Hazards website or app
When consulting the NIOSH Pocket Guide app:
Search by chemical name, or find by alphabetical listing
In chemical specific page, scroll to Exposure Metrics, PPE, or Respirator Recommendations as needed
Chemical Protection: When there is no fire risk, wear appropriate chemical protective clothing and continue atmospheric monitoring for tasks involving entry into or opening (ventilating) the enclosed space. Follow directions from Safety Officer, Operations Chief, or Incident Commander for PPE selection and use.
Indicators that a scene may be a chemical suicide include:
A confined space (e.g., a car or room with closed doors and windows)
Tape or plastic covering the vents and windows
A person showing no signs of trauma
Signs or placards posted by the person warning of toxic gas
A suicide note
Empty cleaning supply, pesticide, or paint containers
Odors such as rotten eggs or bitter almonds
Other personnel near the area complaining of symptoms such as difficulty breathing
Consider apparent deaths from chemical exposures in these situations may be suicides, homicides, or accidents
For more detailed information and pictures on identifying key components of a chemical suicide: https://info.publicintelligence.net/CFIX-ChemicalSuicide.pdf
Carbon Monoxide (CO) suicide is usually achieved by inhaling exhaust from vehicles, generators, or fuel-based heaters in an enclosed space. CO is an odorless, colorless gas that can kill by displacing circulating oxygen.
The same protocols should be followed for CO suicide as for other mixed chemical suicides. The most common chemical mixtures used are Hydrogen Sulfide, Hydrogen Cyanide and Sodium Nitrite due to availability and ease of use.
| Hydrogen Sulfide | Hydrogen Cyanide | Sodium Nitrite | |
|---|---|---|---|
| About | Made by mixing cleaning components containing acid with compounds containing sulfur, like pesticides or insecticides. Creates a gas that asphyxiates on the cellular level. | Created using an acid source and cyanide salts such as sodium cyanide or potassium cyanide. Less common because components harder to obtain. | Sodium Nitrite (NaNO2) is a water-soluble, white-yellow colored crystalline powder typically used as a food preservative, antimicrobial, a coloring agent, and in automotive maintenance. When ingested, it interferes with the ability of red blood cells to transport oxygen, proving fatal. |
| Exposure Route | Inhalation | Mucous membranes, eyes, skin | Ingestion |
| Odor Note: High concentrations can lead to olfactory fatigue, making the scent undetectable |
Rotten egg | Bitter almond | None |
| Symptoms |
|
|
|
| Initial Isolation distance | 100 ft | 200 ft | 150 ft |
| Protective Action Distance | 0.1 miles (day) and 0.3 miles (night) | 0.1 miles (day) and 0.4 miles (night) | Avoid contact with Sodium Nitrite |
| Dangerous Concentration Levels |
|
|
|
| Patient Treatment |
|
|
|
Chemical suicides should be treated as a hazardous materials (HAZMAT) incident and a crime.
When responding:
Size up the event scene
Request a HAZMAT Team and assistance from law enforcement
Wear appropriate PPE and respiratory protection
Secure the area
Attempt to determine whether person is still alive or deceased
Initiate rescue for viable patients
Ventilate the confined space
Perform atmospheric monitoring for toxic gases
Decontaminate those who have been exposed
Begin recovery operations
Protect evidence and prepare for a criminal investigation
Consider additional risks
General guidance on PPE for responding to chemical suicide as follows:
Respiratory Protection: Use a NIOSH-approved self-contained breathing apparatus Self-Contained Breathing Apparatus (SCBA) or combination SCBA and type C supplied-air respirator with full-face mask when entering areas with unknown chemical concentrations or Immediate Danger to Life or Health (IDLH) conditions.
References: NIOSH Pocket Guide to Chemical Hazards website or app
When consulting the NIOSH Pocket Guide app:
Search by chemical name, or find by alphabetical listing
In chemical specific page, scroll to Exposure Metrics, PPE, or Respirator Recommendations as needed
Chemical Protection: When there is no fire risk, wear appropriate chemical protective clothing and continue atmospheric monitoring for tasks involving entry into or opening (ventilating) the enclosed space. Follow directions from Safety Officer, Operations Chief, or Incident Commander for PPE selection and use.